- Shower
- 20 gal per useU.S. DOE Energy Saver, "Sizing a New Water Heater" (archived, Internet Archive snapshot 2026-07-02), peak-hour worksheet. DOE: "Estimates are based on averages from a variety of information published on websites."
- Shaving
- 2 gal per useU.S. DOE Energy Saver, "Sizing a New Water Heater" (archived, Internet Archive snapshot 2026-07-02), peak-hour worksheet. DOE: "Estimates are based on averages from a variety of information published on websites."
- Hand dishwashing or food prep
- 3 gal per useU.S. DOE Energy Saver, "Sizing a New Water Heater" (archived, Internet Archive snapshot 2026-07-02), peak-hour worksheet. DOE: "Estimates are based on averages from a variety of information published on websites."
- Automatic dishwasher
- 7 gal per useU.S. DOE Energy Saver, "Sizing a New Water Heater" (archived, Internet Archive snapshot 2026-07-02), peak-hour worksheet. DOE: "Estimates are based on averages from a variety of information published on websites."
- Clothes washer, top-loader
- 25 gal per useU.S. DOE Energy Saver, "Sizing a New Water Heater" (archived, Internet Archive snapshot 2026-07-02), peak-hour worksheet. DOE: "Estimates are based on averages from a variety of information published on websites."
- Clothes washer, H-axis (front-loader)
- 15 gal per useU.S. DOE Energy Saver, "Sizing a New Water Heater" (archived, Internet Archive snapshot 2026-07-02), peak-hour worksheet. DOE: "Estimates are based on averages from a variety of information published on websites."
- Incoming water, default
- 50 °FU.S. DOE Energy Saver, "Sizing a New Water Heater" (archived, Internet Archive snapshot 2026-07-02): "Unless you know otherwise, assume that the incoming water temperature is 50ºF"
- Outlet, default
- 120 °FU.S. DOE Energy Saver, "Sizing a New Water Heater" (archived, Internet Archive snapshot 2026-07-02): "For most uses, you'll want your water heated to 120ºF"
- Scald caution
- 140 °FU.S. DOE Energy Saver, "Sizing a New Water Heater" (archived, Internet Archive snapshot 2026-07-02): 140 °F "increases the possibility of scalding"
- Federal test rise
- 58 → 125 °F (67 °F)10 CFR 430 Subpart B, Appendix E §§2.3–2.5 (supply 58 °F ± 2); 10 CFR 430 Subpart B, Appendix E (nominal rise 67 °F)
- Heat constant
- 500 Btu/h per gpm per °FSite arithmetic: ~8.34 lb/gal (USGS) × 60 min/h × 1 Btu per lb per °F (EIA Btu definition). A rounded constant: 500.2 at 60 °F, 494.4 at 125 °F. Unconfirmed: No primary (DOE, AHRI, ASHRAE or manufacturer) statement of "500 × gpm × ΔT" was found; do not call it an industry standard.
- Btu per kWh
- 3,412U.S. EIA, Energy conversion calculators ("1 kilowatthour = 3,412 Btu"; NIST: 3,412.14)
- Showerhead, federal maximum
- 2.5 gpm10 CFR 430.32 (eCFR, version 2026-10-01)(p): 2.5 gpm at 80 psi
- Showerhead, WaterSense maximum
- 2 gpmU.S. EPA WaterSense, Showerheads
- Bathroom faucet, federal maximum
- 2.2 gpm10 CFR 430.32 (eCFR, version 2026-10-01)(o): 2.2 gpm at 60 psi
- Bathroom faucet, WaterSense maximum
- 1.5 gpmU.S. EPA WaterSense, Bathroom Faucets
- Kitchen faucet, federal maximum
- 2.2 gpm10 CFR 430.32 (eCFR, version 2026-10-01)(o): 2.2 gpm at 60 psi
- Mains-water model
- NREL Eq. 21NREL, 2014 Building America House Simulation Protocols (NREL/TP-5500-60988), Eq. 21; applied to NOAA NCEI 1991–2020 normals (site arithmetic)
- Electric efficiency
- 100%, if you enter itSite assumption for electric resistance heating (label it "assumption")