A customer asks for the same size as the old heater, or a bigger one, or a switch to tankless. None of those is a sizing method. A tank and a tankless unit are rated in different terms, and each one is sized against a different number from the house.

Below are both methods with worked examples, built on the federal test definitions and the Department of Energy's sizing worksheet. Gas piping, venting, combustion air and electrical circuits are out of scope.

Two ratings, two sizing methods

The federal test procedure for residential water heaters, 10 CFR 430, Subpart B, Appendix E, defines the two numbers you size with:

  • First-hour rating (FHR) applies to tanks and other heaters that don't fire on flow. It estimates the most hot water the heater can deliver in one hour, starting fully heated.
  • Maximum GPM rating applies to flow-activated (tankless) heaters. It is the most hot water per minute the unit delivers in the federal test.

Both tests run with supply water at 58 °F and the outlet set to 125 °F, a nominal 67 °F rise, and the maximum GPM formula scales the measured flow to that 67 °F rise. Keep that in mind: a tankless unit's rated flow assumes a 67 °F rise, and many jobs need more.

Tank size in gallons is not the sizing number either. The FHR depends on tank capacity, heat source and burner or element size, according to DOE's Energy Saver sizing page. That page returns a 404 error as of October 4, 2026, so this guide uses the Internet Archive copy captured July 2, 2026.

Sizing a tank: first-hour rating vs. peak-hour demand

DOE's method is to estimate the household's busiest hour of hot water use and choose a model whose FHR is at least that large.

  1. Pick the busiest hour of the day (morning, noon or evening) and count who is home then.
  2. Count each hot water use in that hour.
  3. Multiply each use by its gallons and add them up. That total is the peak-hour demand.
  4. Find a model with an FHR at least that high. It is printed at the top left of the EnergyGuide label as "Capacity (first hour rating)" and may also appear in the maker's literature.

DOE's worksheet uses these gallons of hot water per use:

UseGallons per use
Shower20
Shaving2
Hand dishwashing or food prep3
Automatic dishwasher7
Clothes washer, top-loader25
Clothes washer, front-loader (H-axis)15

DOE notes that these are estimates based on averages of information published on websites, and that the worksheet does not estimate daily use. If you can measure, measured shower flow × minutes beats a flat 20 gallons.

Worked examples:

  • DOE's own example: 3 showers (60) + 1 shave (2) + 1 hand dishwashing (3) = 65 gallons, so look for an FHR of 65 or more. The archived page prints a total of 66, but its lines add to 65.
  • A busy morning: 2 showers (40) + a top-loader load (25) + the dishwasher (7) + food prep (3) = 75 gallons.
  • Measured: 2 showers at 2.0 gpm for 8 minutes (32) + a front-loader load (15) = 47 gallons.
Fig. 1 The busiest hourDrawn to scale: gallons
DOE's example peak hour, 65 gallons, against the first-hour rating to look for, drawn to scalePeak-hour demand column, to scale: Shower 60 gallons, Shaving 2 gallons, Hand dishwashing or food prep 3 gallons; total 65 gallons. Look for a first-hour rating of at least 65 gallons.132Peak hourFHR to find65 gal≥ 65 gal
  1. Shower3 × 20 gal60 gal
  2. Shaving1 × 2 gal2 gal
  3. Hand dishwashing or food prep1 × 3 gal3 gal
  4. Peak hour65 gal
Fig. 1 — DOE’s example peak hour: 3 showers, 1 shave, 1 hand dishwashing. The uses stack to 65 gallons, the red line a tank’s first-hour rating has to reach.

For heat pump water heaters, DOE notes that the FTC does not require the EnergyGuide label, so take the FHR from the manufacturer's literature.

Recovery, if you want to check a spec sheet. The federal test defines recovery efficiency as the energy delivered to the water divided by the energy content of the fuel used. Gallons recovered per hour = input Btu/h × recovery efficiency ÷ (500 ÷ 60 × rise). Take a 40,000 Btu/h gas tank whose spec sheet lists 78% recovery efficiency, at a 70 °F rise: 40,000 × 0.78 ÷ (8.333 × 70) = 53.49 gallons per hour. A 4,500 W element is 15,354 Btu/h; at 98% it recovers 25.79 gallons per hour. Those efficiencies are examples; use the figures for the unit you're quoting.

Back to contents

Sizing a tankless unit: flow × temperature rise

DOE describes tankless heaters as rated by the maximum temperature rise they can deliver at a given flow. So you need two numbers: flow and rise.

  1. List the fixtures that will run at the same time and add up their flow rates. DOE's example is a 0.75 gpm faucet plus a 2.5 gpm showerhead, or 3.25 gpm. If you don't know a flow, DOE suggests timing a bucket for one minute.
  2. Find the rise: desired outlet temperature minus incoming water temperature. DOE uses 120 °F for most uses and a 50 °F inlet when you don't know better, which gives a 70 °F rise. It mentions 140 °F for dishwashers without internal heaters and cautions that 140 °F raises the risk of scalding.
  3. Output Btu/h = 500 × gpm × rise.
  4. Input = output ÷ the efficiency on the spec sheet. For electric units, kW = Btu/h ÷ 3,412.
  5. Check the unit's published flow-and-rise data at your rise, not just its maximum GPM. For several fixtures at once, see tankless water heater gpm.

Worked example (DOE's numbers): 500 × 3.25 gpm × 70 °F = 113,750 Btu/h into the water. A gas unit with a 95% thermal efficiency (an example; use the spec sheet) needs 113,750 ÷ 0.95 = 119,736.8 Btu/h of input, about 119,700. An electric unit, assuming 100%, needs 113,750 ÷ 3,412 = 33.34 kW, which is 138.9 amps at 240 V. Circuit and conductor sizing come from the electrical code and the manufacturer, not from this arithmetic.

Working backward from a unit: a 199,000 Btu/h input unit at 95%, with 43 °F water in and 120 °F out (a 77 °F rise), delivers at most 199,000 × 0.95 ÷ (500 × 77) = 4.91 gpm.

DOE's rule of thumb is that gas tankless units can typically manage a 70 °F rise at 5 gpm, and electric ones at 2 gpm. That works out to 175,000 Btu/h and 70,000 Btu/h of output (20.52 kW). Because the rated maximum GPM is scaled to a 67 °F rise, the same heat output at a 70 °F rise gives about 4% less flow (67 ÷ 70 = 0.957).

The Btu and kW formula, and why 500 is rounded

One Btu raises one pound of water by 1 °F (EIA). The heat needed per hour is pounds of water per hour × rise, and pounds per hour = gpm × 60 × pounds per gallon. The constant 500 is that 60 × pounds per gallon, rounded: 500 ÷ 60 = 8.33 lb per gallon.

The federal test procedure uses 8.24 lb per gallon for water at 125 °F and a specific heat of 1.00 Btu per lb per °F, which gives 8.24 × 60 = 494.4. So 500 is a rounded constant, about 1.1% above the test-procedure figure, which errs slightly toward more heater. Our calculator uses 500 everywhere so tank and tankless results agree with each other.

For kW, EIA gives 1 kilowatthour = 3,412 Btu, so kW = Btu/h ÷ 3,412.

Incoming water temperature changes the answer

DOE's 50 °F inlet is a placeholder for when you don't know. In the model estimates below, winter mains water runs colder than that in Minneapolis, Chicago and Boston and warmer in Atlanta and Phoenix. The best number is a measured cold-tap temperature in winter; DOE suggests holding a thermometer under a cold faucet.

The next best is an estimate. NREL's 2014 Building America House Simulation Protocols give an equation for daily mains temperature, based on a location's annual average air temperature and the spread between its warmest and coldest months. NREL says it was fitted to data from multiple locations and reflects pipes buried deeper in colder climates. Plugging in NOAA's 1991–2020 normals gives these model estimates. They come from a model, not from measured water.

City (NOAA station)Annual mean airColdest / warmest month mean airColdest mains, modelRise to 120 °F
Atlanta (Hartsfield)63.6 °F44.8 / 80.9 °F58.8 °F (about Jan. 30)61.2 °F
Boston (Logan)51.9 °F29.9 / 74.1 °F47.3 °F (about Feb. 11)72.7 °F
Chicago (O'Hare)51.2 °F25.2 / 75.4 °F45.4 °F (about Feb. 12)74.6 °F
Minneapolis–St. Paul46.9 °F16.2 / 74.3 °F40.4 °F (about Feb. 16)79.6 °F
Phoenix (Sky Harbor)75.6 °F55.8 (Dec.) / 95.5 °F67.4 °F (about Jan. 18)52.6 °F

Worked example: take DOE's 3.25 gpm to 120 °F in Minneapolis in mid-February. The output needed is 500 × 3.25 × 79.6 = 129,350 Btu/h, 13.7% more than at the 50 °F default (37.91 kW for an electric unit). Flip it around: a unit sized to deliver 113,750 Btu/h gives only 113,750 ÷ (500 × 79.6) = 2.86 gpm at that rise, not 3.25. In Atlanta the model's coldest value is above 50 °F, so the default leaves some margin there.

Where the codes and the manufacturer take over

This is general information, not code or engineering advice. Venting, gas pipe sizing, combustion air, relief valves, electrical circuits and any temperature-limiting devices at fixtures are governed by the adopted codes and the manufacturer's installation instructions. The local building department, as the authority having jurisdiction, has the final word.

You can read the model codes free online: the IPC at ICC Digital Codes, the UPC at IAPMO's read-online library, and the NEC through NFPA free access, which requires an NFPA account. Check which edition and local amendments your jurisdiction has adopted.

Back to contents

Next step

Run the job's numbers in the water heater size calculator. It gives peak-hour gallons for a tank, and Btu/h and kW for a tankless unit, at the inlet temperature you enter. Then use how to price a water heater replacement to turn the unit into a price. If the complaint is a long wait for hot water rather than running out, the heater's size won't fix it; the piping volume will tell you why (gallons in a pipe by size).

Sources

  1. Sizing a New Water Heater (archived copy, captured July 2, 2026; live page returns 404)U.S. Department of Energy, Energy Saver (via Internet Archive)
  2. Appendix E to Subpart B of Part 430, Title 10: Uniform Test Method for Measuring the Energy Consumption of Water HeaterseCFR (Office of the Federal Register)
  3. British thermal units (Btu)U.S. Energy Information Administration
  4. 2014 Building America House Simulation Protocols (NREL/TP-5500-60988)National Renewable Energy Laboratory (via OSTI)
  5. U.S. Climate Normals (1991-2020)NOAA National Centers for Environmental Information
  6. 2024 International Plumbing Code (IPC)International Code Council, Digital Codes
  7. Read IAPMO Codes OnlineIAPMO
  8. Free access NFPA codes and standardsNational Fire Protection Association

Tools for the job

Tool listHVAC + Plumbing3 itemsSpecs read

As an Amazon Associate, Trade Price Book earns from qualifying purchases. Amazon links are marked “(paid link)”; prices aren’t shown here.

  1. Airflow and static pressureFieldpiece SDMN6

    SDMN6 Dual Port Manometer and Pressure Switch Tester

    • Dual-port manometer reading to ±60 inWC at 0.01 inWC resolution (±0.02 inWC up to 2 inWC).

    Specs: Fieldpiece product page, read

    View on Amazon for Fieldpiece SDMN6(paid link)

  2. Combustion and electrical testingtesto 0564 3002 82

    Next-Gen testo 300 Smoke Edition Combustion Analyzer Kit

    • Kit: testo 300 with O2 sensor and CO sensor (0 to 4,000 ppm), mains unit, basic flue-gas probe, spare filters, EasyHeat software, case and Bluetooth connector.

    Specs: testo product page, read

    View on Amazon for testo 0564 3002 82(paid link)

  3. Testing and water heater serviceMilwaukee 2771-20

    M18 Transfer Pump

    • Self-priming pump that moves up to 480 gallons per hour, with up to 18 ft of lift and 75 ft of head height.

    Specs: Milwaukee product page, read

    View on Amazon for Milwaukee 2771-20(paid link)

How tools are chosen for gear listsAll 20 HVAC tools

Newsletter

Get an e-mail when Trade Price Book publishes something new

At most one e-mail a day, only about new guides and tools. No tracking pixels. How we handle your address